How do I set the PCO-7810’s pulse frequency (pulse repetition rate)?

Watch the Video A trigger source sets the pulse frequency. Either the PCO-7810’s internal trigger source, or an external source, can be used. (The width of the pulse is fixed and varies with the model.) Due to power dissipation limits, each model has a maximum specified pulse frequency. Specifically: The PCO-7810-40-4 can output pulses up to 40 A at rates up to 200 kHz, but it requires forced air cooling above…